Valkyrie Knowledge Base

Use The EXT Port On The Chassis

The “Ext” port is pre-configured with the following IP setup:

Address = 172.16.255.200
Subnet = 255.255.255.0
Gateway = none
You must configure your PC port statically to an IP address in the 172.16.255.x range, and then you will be able to ping the chassis again.

Now start ValkyrieManager, and connect to the chassis using the IP address 172.16.255.200.

Under the Chassis Resource Properties you can see which IP address is configured for the “Mgmt” port, and you can reserve the chassis and change it if necessary. Changes to the IP address of the “Mgmt” port take effect after rebooting the chassis.

Note that the IP configuration of the “Ext” port cannot be changed, and that you should not configure the “Mgmt” port to use this subnet.