1. Enable AN-LT in both DUT and THOR. Select the THOR port -> Resource Properties -> PCS/PMA Config & Status -> Enable Autoneg
2. Select the chassis which you are using, then click the “Open ScriptClient” to run the script client.
3. Input the commands to check AN/LT status
4. Commands:
Link Training Status: module/port PP_LINKTRAINSTATUS [line id] ?
For example: 9/0 PP_LINKTRAINSTATUS [0] ?
Return Result: 9/0 PP_LINKTRAINSTATUS [0] ENABLED TRAINED NO_FAILURE
Auto-negotiation Status: module/port PP_AUTONEGSTATUS ?
For example: 9/0 PP_AUTONEGSTATUS ?
Return result: 9/0 PP_AUTONEGSTATUS ANEG_ON RS_FEC AN_GOOD IEEE_200GBASE_CR4_KR4 DEFAULT_FEC RSFEC_CL91 NO_PAUSE